iten
  • Crawlspace

    Vespaio areato Colosseo con tegoplastVentilated crawlspace ColosseoIt is easily used, the elements extreme lightness
    and rigidiness makes the laying stage quick and safe. TEGOPLAST is furnished of channels at the ends of it, facilitating its support
    on the ARCOPLAST rows.
  • Floors

    Solai con tegoplastFloors with tegoplastTEGOPLAST can be employed to build floor support structures
    made of reinforced concrete rather than traditional lug bricks or other materials.
  • Underground Walls

    Isolamento pareti interrateProtection and Insulation of Underground WallsTEGOPLAST (size 75cm X 42 cm x h10.5) combined with some additional elements (grid, plugs, fixing elements, flexible angled junctions, etc.) can be used to effectively insulate and ventilate underground walls.
  • Insulation

    Isolamento pareti interrateFloors ElevationTEGOPLAST can be used in an effective way to isolate and ventilate coverings, solar pavings and floor elevation.
    It creates an interspace which avoids the condensate formation and favours
    the heat insulation in the below environments.
Technical Card PDF Print E-mail
Ventilated crawlspace Colosseo height from cm 45 to 200
(wheelbase between supports cm 96 / 50)


Technical characteristics ventilated crawlspace Colosseo for height from cm 45 to 200
A
B
C
D
E
P
UsePermanent and accidental overload
(kg/sqm)
Weight (including slab)
(kg/sqm)
Slab thickness (cm)
Metal
armour
Pressure of the bearing on
the bedding (kg/sq cm)
P = B+C/(2 x S.p.a.)
h*** (cm)
h (cm)
45
75
125
200
45
75
125
200
Residential buildings
400
243
260
287
326
4
Ø 5/20x20 2,89
2,97
3,09
3,26
Civil buildings
500
243260
287
326
4
Ø 6/20x20
3,34
3,42
3,54
3,71
Garages
600
268285
312
351
5
Ø 6/20x20
3,90
3,98
4,10
4,27
Storerooms
Laboratories
Warehouses
Factories
800
293
310
337
376
6
Ø 6/20x20
4,91
4,99
5,11
5,29
Light floors for industry **
7000
343
360
387
426
8
Ø 8/20x20
+ 1 Ø 8 long.
+ 1 Ø 8 ad “U” vert.
33,01
33,09
33,21
33,38
Heavy floors for industry**
10000
468
485
512
551
13
Ø 8/20x20
+ 1 Ø 8 long.
+ 1 Ø 8 ad “U” vert.
47,06
47,14
47,26
47,43
 
In case of height over 125 cm and special overloads please take into account the need of an extr rebar. The designer has to assess the quantity of necessary rebar.
* Permanent and accidental overload are represented by all active loads except the weight of the structure itself. Permanent overloads have been estimated as 200 kg / sq m.
** Concrete: for vertical structure, Rck 25; for upper slab Rck 30/S4; fibre-armed with 20kg/cube m steel fibre.
*** The heights in C and P columns are examples in order to represent real data on hypothetical heights.
PIECES IMPACT / SQM
CONCRETE CONSUMPTION
    Filling of the razed crawlspace with
h of 45 cm
Filling pipe for heights over 45 cmFor the upper slab
BASE ARCO
ARCO.3550TEGO.1275C
TUBO PVC
Ø 125 mm
lt / sqm
lt / sqm x cm
lt / sqm x cm
2
2
2,5
255
0.22
10
1) Per altezze del Vespaio maggiori di cm 45 fino a 200 inserire prolunga di tubo in PVC Ø 125 mm, spessore mm 2,3;
2) Calcolo lunghezza del tubo: esempio, vespaio h cm 100 a raso = ( 100 - 45) = 55 cm a cui vanno aggiunti cm 5 di imbocco;
3)Lo spessore della soletta superiore va determinato in base al sovraccarico del vespaio
 
< Prev

Specifications

Making of the Colosseo crawlspace in order to guarantee an insulation between the foundation and the flooring with the creation of a sanitary space. It is made with modular elements in recycled plastic, equipped with a certification for a minimum breaking load of 150 kg, concentrated on a surface of 5x5 cm. The afore mentioned crawlspace is composed of: vertical structure (ARCOPLAST) h 35 x L 50 x Φ 12,5 cm including the base Φ 20, linked and fixed together with a 50 cm wheelbase blocked with a 6 cm nails inserted in the special holes, arranged in parallel rows with a 96 cm wheelbase, possible PVC pipes Φ 12,5 cm for heights over 45 cm and close TEGOPLAST horizontal elements whose sizes are 82x42 hooked between them and laid on the vertical structure. Cutting and (if necessary) anchoring are included in the foundations. This guarantees the concrete casting necessary to lay the crawlspace. The following are not included: Supplying and laying of concrete, electrosoldering net, the possible supplementary armour and needed ventilation openings, concrete necessary to lay the surface of the crawlspace, filling of the razed element and for the upper slab.
1) For a razed height of 45 cm € ...... sqm 2.
2) For a razed height > 45 cm € .... cm x sqm.
RocketTheme Joomla Templates