iten
  • Floors

    Solai con tegoplastFloors with tegoplastTEGOPLAST can be employed to build floor support structures
    made of reinforced concrete rather than traditional lug bricks or other materials.
  • Crawlspace

    Vespaio areato Colosseo con tegoplastVentilated crawlspace ColosseoIt is easily used, the elements extreme lightness
    and rigidiness makes the laying stage quick and safe. TEGOPLAST is furnished of channels at the ends of it, facilitating its support
    on the ARCOPLAST rows.
  • Underground Walls

    Isolamento pareti interrateProtection and Insulation of Underground WallsTEGOPLAST (size 75cm X 42 cm x h10.5) combined with some additional elements (grid, plugs, fixing elements, flexible angled junctions, etc.) can be used to effectively insulate and ventilate underground walls.
  • Insulation

    Isolamento pareti interrateFloors ElevationTEGOPLAST can be used in an effective way to isolate and ventilate coverings, solar pavings and floor elevation.
    It creates an interspace which avoids the condensate formation and favours
    the heat insulation in the below environments.
Technical Card PDF Print E-mail
Floor with Tegoplast and NP or IPE iron beams
(Wheelbase max 85 cm)


 Art. codeFLOOR HEIGHT
H (cm)
TEGOPLASTIron beamsFinishing mass concrete (l/sqm)
 Cast structure weight (kg/sqm)
H
h
sHPieces
/ sqm

Weight
(kg/sqm)
 Weight kg/sqm
Wheelbase
Filling razed
beam
upper slab (s)
with
NP beam
with
IPE beam
 NP IPE
  TEGO.1275C14
10
4
3
2,80
6,89
16,82
15,17
85,054,00
30
171,30
169,70
16
6
21,05
18,58
74,00
30
203,50201,10
  TEGO.1675C
18
14
4
4
2,807,03
25,75
22,11
85,0
62,00
40
215,60
211,90
20
6
5
30,81
26,34
82,0050
272,60
268,20
  TEGO.2075C
22
18
4
5
2,808,26
36,46
30,81
85,0
70,00
50
262,70
257,10
 The following specific weights have been taken into consideration for the calculation of the floor specific weight: 1400 kg/m3 for the level beam filling light concrete and 2.400 kg/m3 for the upper slab.
Tegoplast and iron beams combining represents just one example, the choice is at the discretion of the designer.
 
Next >

Specifications

Floor mixed structure with double T iron beams “NP or IPE” H ... ( to be computed separately) and TEGOPLAST modular elements in recycled plastic, dimensions 42 x 81 with a height ..., including transversal links between the beams, the distribution net to be computed separately, the supplying of the filling light concrete at a level beam and the upper slab in cls with a thickness ... and each obligation and mastery € ... sqm.
RocketTheme Joomla Templates