iten
  • Floors

    Solai con tegoplastFloors with tegoplastTEGOPLAST can be employed to build floor support structures
    made of reinforced concrete rather than traditional lug bricks or other materials.
  • Crawlspace

    Vespaio areato Colosseo con tegoplastVentilated crawlspace ColosseoIt is easily used, the elements extreme lightness
    and rigidiness makes the laying stage quick and safe. TEGOPLAST is furnished of channels at the ends of it, facilitating its support
    on the ARCOPLAST rows.
  • Underground Walls

    Isolamento pareti interrateProtection and Insulation of Underground WallsTEGOPLAST (size 75cm X 42 cm x h10.5) combined with some additional elements (grid, plugs, fixing elements, flexible angled junctions, etc.) can be used to effectively insulate and ventilate underground walls.
  • Insulation

    Isolamento pareti interrateFloors ElevationTEGOPLAST can be used in an effective way to isolate and ventilate coverings, solar pavings and floor elevation.
    It creates an interspace which avoids the condensate formation and favours
    the heat insulation in the below environments.
Casting mixed floors in reinforced concrete with parallel or crossed ribbing casting and tegoplast PDF Print E-mail
These kinds of floors, lightened using TEGOPLAST elements, represent a valid solution to make building plankings characterized by planimetric irregularity, vaults, projecting parts, unavalaibility of the prefabricated structural elements or lack of spaces allowing the access to the lifting means in the yard. They are fully made on site upon wooden scaffoldings.
These kinds of floors are classified according to the Ministerial decree 09/01/1996 as concrete and reinforced concrete mixed floors and lightening blocks.


PARALLEL RIBBING FLOORS
Open TEGOPLAST with supporting pins are used for these kinds of floors. They are lined up to a minimum changeable wheelbase of 50 cm.


CROSSED RIBBING FLOORS
Closed TEGOPLAST in the version "interposed ends between orthogonal ribbing with changeable wheelbase" are used for crossed floors with plate functioning. They allow a high carrying capacity with relatively advantageous costs compared to the traditional solutions.


 
< Prev   Next >

Specifications

Inclined or flat floor support structure, ... high, made of pre-stressed or reinforced concrete rafters and TEGOPLAST modular and plastic-recycled elements – including the plug closures to place at the ends of the lines, other devices such as temporary plug closures and similar.
Installed in an interfloor gap not above 3.5 mt high, it is endowed with parallel ribs, iron cast reinforcement, installation frame (to be paid extra), joists, concrete to fill up the rafters and the upper concrete slab, including frames.

Up to light ml... and thickness of cm... for overload of kg ... / sqm € ... sqm