iten
  • Floors

    Solai con tegoplastFloors with tegoplastTEGOPLAST can be employed to build floor support structures
    made of reinforced concrete rather than traditional lug bricks or other materials.
  • Crawlspace

    Vespaio areato Colosseo con tegoplastVentilated crawlspace ColosseoIt is easily used, the elements extreme lightness
    and rigidiness makes the laying stage quick and safe. TEGOPLAST is furnished of channels at the ends of it, facilitating its support
    on the ARCOPLAST rows.
  • Underground Walls

    Isolamento pareti interrateProtection and Insulation of Underground WallsTEGOPLAST (size 75cm X 42 cm x h10.5) combined with some additional elements (grid, plugs, fixing elements, flexible angled junctions, etc.) can be used to effectively insulate and ventilate underground walls.
  • Insulation

    Isolamento pareti interrateFloors ElevationTEGOPLAST can be used in an effective way to isolate and ventilate coverings, solar pavings and floor elevation.
    It creates an interspace which avoids the condensate formation and favours
    the heat insulation in the below environments.
Technical Card PDF Print E-mail
Mixed floor with TEGOPLAST and prefabricated rafters in reinforced concrete
(Single wheelbase joist 50 cm)


 Art. codeFLOOR HEIGHT (cm)
TEGOPLASTRafters weight
(kg/sqm)
Finishing mass
concrete **
(l/sqm)
Cast structure weight
(kg/sqm)
h
sHPieces
/sqm
Weight
(kg/sqm)
flush
slab
  TEGO.127512
4
16
2,66
5,85
36,0021,6040,00
189,70
5
17
50,00
213,70
6
18
60,00
237,70
  TEGO.1675
164
202,66
6,25
36,0035,2040,00222,70
5
2150,00246,70
6
2260,00270,70
  TEGO.2075
204242,667,05
36,0046,9040,00251,60
525
50,00275,60
626
60,00299,60
  TEGO.2575
254292,667,7136,0067,5040,00301,70
539
50,00325,70
631
60,00349,70
 ** To calculate the concrete weight, the specific weight of 2,40 / l has been taken into consideration
 
< Prev

Specifications

Inclined or flat floor support structure, ... high, made of pre-stressed or reinforced concrete rafters and TEGOPLAST modular and plastic-recycled elements – including the plug closures to place at the ends of the lines, other devices such as temporary plug closures and similar.
Installed in an interfloor gap not above 3.5mt high, it is endowed with parallel ribs, iron cast reinforcement, installation frame (to be paid extra), rafters, concrete to fill up the rafters and the upper concrete slab, including frames.

A) Up to lights of ml ... and thickness of cm. ... for an overload of Kg ... /sqm € ... for each sqm

B) Increase in price if trellis prefabricated joists are used, together with a brick base € ... for each sqm
RocketTheme Joomla Templates